Reyun Lyd7 Series Surge Protective Device Surge Controller SPD T2 Class II Imax 20ka to 80ka

IEC 61643-11: Class II
En 61643-11: Type 2
UC: 420VAC / 385VAC / 320VAC
Imax: 80ka / 60ka / 40ka / 20ka
in: 40ka / 30ka / 20ka / 10ka
Pole Version: 1-Pole 2-Pole 3-Pole 4-Pole
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Installation Instructions
  • FAQ
Overview

Basic Info.

Model NO.
LYD7
Transportation Carton
31cm*25cm*32cm
Mounting
DIN Rail 35mm
Transport Package
Paper Carton
Specification
Imax 80kA 60kA 40kA 20kA
Trademark
reyun
Origin
China
HS Code
8536300000
Production Capacity
100000 Per Month

Product Description

Product Description

IEC 61643-11 Class II

EN 61643-11 Type 2

Test type : 8/20μs

Surge Protective Device LYD7 seris

Maximum discharge current (Imax): 80kA / 60kA / 40kA / 20kA

Maximum continuous operation voltage (Uc): 420VAC / 385VAC / 320VAC

Pole version: 1-pole, 2-pole, 3-pole, 4-pole

Remote signalling: select-able.

DIN rail 35mm mounted

Used for low voltage distribution system.

Detailed Photos
Reyun Lyd7 Series Surge Protective Device Surge Controller SPD T2 Class II Imax 20ka to 80ka
@ IEC 61643-11 Class II
@ EN 61643-11 Type 2
@ Pole version: 1-pole, 2-pole, 3-pole, 4-pole
@ Maximum discharge current (Imax): 80kA / 60kA / 40kA / 20kA
@ Warranty 3 years
@ Remote signalling function is select-able
Product Parameters

LYD7 series surge protective device, Maximum discharge current 80kA , 4 variants, 420VAC

Model LYD7-B80-1-420 LYD7-B80-2-420 LYD7-B80-2-420 LYD7-B80-4-420
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 420VAC
Maximum discharge current 8/20μs (Imax) 80kA
Nominal discharge current 8/20μs (In) 40kA
Voltage protection level (Up) <=2.3kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 60kA , 4 variants, 420VAC
Model LYD7-B60-1-420 LYD7-B60-2-420 LYD7-B60-3-420 LYD7-B60-4-420
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 420VAC
Maximum discharge current 8/20μs (Imax) 60kA
Nominal discharge current 8/20μs (In) 30kA
Voltage protection level (Up) <=2.2kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 40kA , 4 variants, 420VAC
Model LYD7-C40-1-420 LYD7-C40-2-420 LYD7-C40-3-420 LYD7-C40-4-420
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 420VAC
Maximum discharge current 8/20μs (Imax) 40kA
Nominal discharge current 8/20μs (In) 20kA
Voltage protection level (Up) <=2.0kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 20kA , 4 variants, 420VAC
Model LYD7-D20-1-420 LYD7-D20-2-420 LYD7-D20-3-420 LYD7-D20-4-420
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 420VAC
Maximum discharge current 8/20μs (Imax) 20kA
Nominal discharge current 8/20μs (In) 10kA
Voltage protection level (Up) <=1.8kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 80kA , 4 variants, 385VAC

Model LYD7-B80-1-385 LYD7-B80-2-385 LYD7-B80-2-385 LYD7-B80-4-385
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 80kA
Nominal discharge current 8/20μs (In) 40kA
Voltage protection level (Up) <=2.2kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 60kA , 4 variants, 385VAC
Model LYD7-B60-1-385 LYD7-B60-2-385 LYD7-B60-3-385 LYD7-B60-4-385
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 60kA
Nominal discharge current 8/20μs (In) 30kA
Voltage protection level (Up) <=2.0kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 40kA , 4 variants, 385VAC
Model LYD7-C40-1-385 LYD7-C40-2-385 LYD7-C40-3-385 LYD7-C40-4-385
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 40kA
Nominal discharge current 8/20μs (In) 20kA
Voltage protection level (Up) <=1.8kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 20kA , 4 variants, 385VAC
Model LYD7-D20-1-385 LYD7-D20-2-385 LYD7-D20-3-385 LYD7-D20-4-385
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 20kA
Nominal discharge current 8/20μs (In) 10kA
Voltage protection level (Up) <=1.5kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 80kA , 4 variants, 320VAC

Model LYD7-B80-1-320 LYD7-B80-2-320 LYD7-B80-2-320 LYD7-B80-4-320
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 320VAC
Maximum discharge current 8/20μs (Imax) 80kA
Nominal discharge current 8/20μs (In) 40kA
Voltage protection level (Up) <=2.0kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 60kA , 4 variants, 320VAC
Model LYD7-B60-1-320 LYD7-B60-2-320 LYD7-B60-3-320 LYD7-B60-4-320
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 320VAC
Maximum discharge current 8/20μs (Imax) 60kA
Nominal discharge current 8/20μs (In) 30kA
Voltage protection level (Up) <=1.8kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 40kA , 4 variants, 320VAC
Model LYD7-C40-1-320 LYD7-C40-2-320 LYD7-C40-3-320 LYD7-C40-4-320
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 320VAC
Maximum discharge current 8/20μs (Imax) 40kA
Nominal discharge current 8/20μs (In) 20kA
Voltage protection level (Up) <=1.6kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 20kA , 4 variants, 320VAC
Model LYD7-D20-1-320 LYD7-D20-2-320 LYD7-D20-3-320 LYD7-D20-4-320
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 320VAC
Maximum discharge current 8/20μs (Imax) 20kA
Nominal discharge current 8/20μs (In) 10kA
Voltage protection level (Up) <=1.4kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 80kA , 4 variants, 420VAC, with remote signalling

Model LYD7-B80-1-420-FS LYD7-B80-2-420-FS LYD7-B80-2-420-FS LYD7-B80-4-420-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 420VAC
Maximum discharge current 8/20μs (Imax) 80kA
Nominal discharge current 8/20μs (In) 40kA
Voltage protection level (Up) <=2.3kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling Yes

LYD7 series surge protective device, Maximum discharge current 60kA , 4 variants, 420VAC, with remote signalling
Model LYD7-B60-1-420-FS LYD7-B60-2-420-FS LYD7-B60-3-420-FS LYD7-B60-4-420-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 420VAC
Maximum discharge current 8/20μs (Imax) 60kA
Nominal discharge current 8/20μs (In) 30kA
Voltage protection level (Up) <=2.2kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling Yes

LYD7 series surge protective device, Maximum discharge current 40kA , 4 variants, 420VAC, with signalling
Model LYD7-C40-1-420-FS LYD7-C40-2-420-FS LYD7-C40-3-420-FS LYD7-C40-4-420-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 420VAC
Maximum discharge current 8/20μs (Imax) 40kA
Nominal discharge current 8/20μs (In) 20kA
Voltage protection level (Up) <=2.0kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling Yes

LYD7 series surge protective device, Maximum discharge current 20kA , 4 variants, 420VAC. With signalling
Model LYD7-D20-1-420-FS LYD7-D20-2-420-FS LYD7-D20-3-420-FS LYD7-D20-4-420-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 420VAC
Maximum discharge current 8/20μs (Imax) 20kA
Nominal discharge current 8/20μs (In) 10kA
Voltage protection level (Up) <=1.8kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling Yes

LYD7 series surge protective device, Maximum discharge current 80kA , 4 variants, 385VAC

Model LYD7-B80-1-385 LYD7-B80-2-385 LYD7-B80-2-385 LYD7-B80-4-385
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 80kA
Nominal discharge current 8/20μs (In) 40kA
Voltage protection level (Up) <=2.2kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 60kA , 4 variants, 385VAC
Model LYD7-B60-1-385 LYD7-B60-2-385 LYD7-B60-3-385 LYD7-B60-4-385
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 60kA
Nominal discharge current 8/20μs (In) 30kA
Voltage protection level (Up) <=2.0kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 40kA , 4 variants, 385VAC
Model LYD7-C40-1-385 LYD7-C40-2-385 LYD7-C40-3-385 LYD7-C40-4-385
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 40kA
Nominal discharge current 8/20μs (In) 20kA
Voltage protection level (Up) <=1.8kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 20kA , 4 variants, 385VAC
Model LYD7-D20-1-385 LYD7-D20-2-385 LYD7-D20-3-385 LYD7-D20-4-385
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 20kA
Nominal discharge current 8/20μs (In) 10kA
Voltage protection level (Up) <=1.5kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect

LYD7 series surge protective device, Maximum discharge current 80kA , 4 variants, 385VAC, with remote signalling
Model LYD7-B80-1-385-FS LYD7-B80-2-385-FS LYD7-B80-2-385-FS LYD7-B80-4-385-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 80kA
Nominal discharge current 8/20μs (In) 40kA
Voltage protection level (Up) <=2.2kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling yes

LYD7 series surge protective device, Maximum discharge current 60kA , 4 variants, 385VAC, with remote signalling
Model LYD7-B60-1-385-FS LYD7-B60-2-385-FS LYD7-B60-3-385-FS LYD7-B60-4-385-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 60kA
Nominal discharge current 8/20μs (In) 30kA
Voltage protection level (Up) <=2.0kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling yes

LYD7 series surge protective device, Maximum discharge current 40kA , 4 variants, 385VAC, with signalling
Model LYD7-C40-1-385-FS LYD7-C40-2-385-FS LYD7-C40-3-385-FS LYD7-C40-4-385-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 40kA
Nominal discharge current 8/20μs (In) 20kA
Voltage protection level (Up) <=1.8kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling yes

LYD7 series surge protective device, Maximum discharge current 20kA , 4 variants, 385VAC, with remote signalling
Model LYD7-D20-1-385-FS LYD7-D20-2-385-FS LYD7-D20-3-385-FS LYD7-D20-4-385-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 385VAC
Maximum discharge current 8/20μs (Imax) 20kA
Nominal discharge current 8/20μs (In) 10kA
Voltage protection level (Up) <=1.5kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling yes

LYD7 series surge protective device, Maximum discharge current 80kA , 4 variants, 320VAC, with remote signalling

Model LYD7-B80-1-320-FS LYD7-B80-2-320-FS LYD7-B80-2-320-FS LYD7-B80-4-320-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 320VAC
Maximum discharge current 8/20μs (Imax) 80kA
Nominal discharge current 8/20μs (In) 40kA
Voltage protection level (Up) <=2.0kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling yes

LYD7 series surge protective device, Maximum discharge current 60kA , 4 variants, 320VAC, with remote signalling
Model LYD7-B60-1-320-FS LYD7-B60-2-320-FS LYD7-B60-3-320-FS LYD7-B60-4-320-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 320VAC
Maximum discharge current 8/20μs (Imax) 60kA
Nominal discharge current 8/20μs (In) 30kA
Voltage protection level (Up) <=1.8kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling yes

LYD7 series surge protective device, Maximum discharge current 40kA , 4 variants, 320VAC, with remote signalling
Model LYD7-C40-1-320-FS LYD7-C40-2-320-FS LYD7-C40-3-320-FS LYD7-C40-4-320-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 320VAC
Maximum discharge current 8/20μs (Imax) 40kA
Nominal discharge current 8/20μs (In) 20kA
Voltage protection level (Up) <=1.6kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling yes

LYD7 series surge protective device, Maximum discharge current 20kA , 4 variants, 320VAC, with remote signalling
Model LYD7-D20-1-320-FS LYD7-D20-2-320-FS LYD7-D20-3-320-FS LYD7-D20-4-320-FS
Pole version 1-pole 2-pole 3-pole 4-pole
Maximum continuous operation voltage (Uc) 320VAC
Maximum discharge current 8/20μs (Imax) 20kA
Nominal discharge current 8/20μs (In) 10kA
Voltage protection level (Up) <=1.4kV
Response time <=25ns
Degree of protection IP20
Temperature range -40°C to +80°C
The visual window of defect Green is normal, red is defect
Remote signalling yes

 

Installation Instructions

(1) Install by DIN rail 35mm.
(2) Scale drawing

Reyun Lyd7 Series Surge Protective Device Surge Controller SPD T2 Class II Imax 20ka to 80ka

FAQ

OEM/ODM customerize is available.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area
>2000 square meters